Description
The Fluke 114 hand held digital TRMS multimeter is an affordable tool for electrical troubleshooting. The beautiful 6,000 count display allows for working in poorly lit environments with 28% larger digits as well as a large white LED backlight. A simple 9 volt alkaline battery will keep you testing, without the backlight, for 400 hours. With a three year warranty, if you need to measure Volt/Ohm this meter will be your assistant for years to come.
Designed by electricians. Engineered by Fluke.
Designed for easy one-hand operation, the Fluke 114 true-rms digital multimeter is the perfect troubleshooting tool for “go/no go testing. The LoZ function helps to prevent false readings caused by ghost voltage.
Also check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.
Safety conformance.
All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE.
Comparison Chart.
Current | New | ||||||||
Basic features | 110 | 111 | 112 | 12 | 16 | 114 | 115 | 116 | 117 |
True RMS readings | AC | AC | AC | AC | AC | AC | AC | ||
Basic DC accuracy | 0.7% | 0.7% | 0.7% | 0.9% | 0.9% | 0.5% | 0.5% | 0.5% | 0.5% |
Digits | 3-1/2 | 3-1/2 | 3-1/2 | 3-1/2 | 3-1/2 | 3-1/2 | 3-1/2 | 3-1/2 | 3-1/2 |
Counts | 6000 | 6000 | 6000 | 4000 | 4000 | 6000 | 6000 | 6000 | 6000 |
Measurements | |||||||||
Voltage AC/DC | 600V | 600V | 600V | 600V | 600V | 600V | 600V | 600V | 600V |
Current AC/DC | 10A | 10A | 200µA | 10A | 600µA | 10A | |||
Resistance | 40MO | 40MO | 40MO | 40MO | 40MO | 40MO | 40MO | 40MO | 40MO |
Frequency | 50kHz | 50kHz | 50kHz | 50kHz | 50kHz | 50kHz | |||
Capacitance | 10mF | 10mF | 10mF | 10mF | 10mF | 10mF | 10mF | 10mF | |
Temperature | +400°C | +400°C | |||||||
Display | |||||||||
Analog bargraph | • | • | • | • | • | • | • | ||
Backlight | • | • | • | • | • | ||||
Data storage and exchange | |||||||||
Min-Max recording | • | • | • | • | • | • | • | • | |
Display Hold/Auto (Touch) Hold | • | • | • | • | • | • | • | ||
Other features | |||||||||
Automatic selection, VChek | • | • | |||||||
Automatic selection, LoZ | • | • | • | ||||||
Volt Alert, Non Contact ac voltage detector | • |
In The Box
- Fluke TL75 Test leads
- Holster
- User’s Manual
- 9 V battery (installed)
Manufacturer Specs
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %.
The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] ) |
Maximum voltage between any terminal and earth ground | 600 V |
Surge protection | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Display | Digital: 6,000 counts, updates 4/sec |
Bar graph | 33 segments, updates 32/sec |
Operating temperature | -10 °C to + 50 °C |
Storage temperature | -40 °C to + 60 °C |
Battery | 9 volt Alkaline, NEDA 1604A/IEC 6LR61 |
Battery life | 400 hours typical, without backlight |
Measurement | Range | Resolution | Accuracy ± ([% of reading] + [counts]) |
DC millivolts | 600.0 mV | 0.1 mV | 2.0 % + 3 |
DC volts | 6.000 V | 0.001 V | |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
Auto volts | 600.0 V | 0.1 V | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms | 600.0 mV | 0.1 mV | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms | 6.000 V | 0.001 V | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
Continuity | 600 W | 1 W | Beeper on < 20 W, off > 250 W; detects opens or shorts of 500 µs or longer. |
Ohms | 600.0 W | 0.1 W | 0.9 % + 2 |
6.000 kW | 0.001 kW | 0.9 % + 1 | |
60.00 kW | 0.01 kW | ||
600.0 kW | 0.1 kW | ||
6.000 MW | 0.001 MW | ||
40.00 MW | 0.01 MW | 1.5 % + 2 |
All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of = 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. |
Reviews
There are no reviews yet.